VENABLE TECHNICAL REFERENCE LIBRARY ABSTRACT - 18

New Techniques for Measuring
Feedback Loop Transfer Functions
in Current Mode Converters

In power supplies with current mode control topology, the current feedback forms an internal digital loop that cannot be directly measured. The phase margin of this loop is a function of duty cycle, and this loop can become unstable for duty cycles greater than fifty percent. Although techniques such as slope compensation can be used to adjust the stability of this internal feedback loop, measurement of this loop is essential to verify the effectiveness of the adjustment. This paper describes techniques for indirect measurement of the gain-phase characteristics (Bode plot) of this feedback loop. If also describes how to use this information to optimize the performance of the overall voltage feedback loop. Finally, the paper describes how to measure the feedback loop of power supplies where no single signal injection point is available.